VCM-EE in Explosion-Proof Enclosure
MPS’ most popular model in a protected explosion-proof enclosure. Applicable for Explosion-Proof Environments.
For the most complete protection on large, or critical machines, the VCM-E is ideal due to its higher shaft current measurement capacity, uninterrupted grounding, continuous monitoring via 4-20mA signals and alarms for alerting operators to dangerous conditions such as brush performance failure or increase in shaft voltage. VCM-E’s continuously monitor shaft voltage and/or grounding/earthing current providing three 4‑20 mA output signals (per VCM-E) for remote monitoring and trending.
- Explosion Proof
- Prevent Shaft Current Damage
- Shaft Current Sparking Confined or Controlled
- Train Performance Tracking, Aiding Operation
- Continuous Train Performance Sensing and Tracking
- Continuous Train Trending Aiding in Maintenance Scheduling
-
- Alarms when shaft grounding devices have lost contact with the shaft.
- Alarms on high and low grounding current and/or high shaft voltage.
| OUTPUTS per VCM-E: | ||
| Monitoring: | ||
| Local: | 3½ digit liquid crystal display indicating Peak Current, Average Current, Peak Shaft Voltage** and Power/Alarm Check, selected with rotary switch. | |
| Remote: |
|
|
| Alarms : | ||
| Local: | LED for minimum and maximum grounding current and maximum shaft voltage.** | |
| Remote: | Open contact on minimum and maximum current, maximum voltage and loss of power supply to the unit. (User selectable latching is optionally available in Non-Explosion-Proof Enclosures Only) | |
| INPUT per VCM-E: |
Ground Current Lead (from shunt in grounding device circuit). Voltage Lead (from separate voltage sensing device/system)PLEASE NOTE: MPS VCMs will operate with any Vendor’s Shaft Grounding or Voltage Sensing Devices |
|
| POWER REQUIREMENTS: | 100 VAC to 240 VAC, 60/50 Hz. | |
| HARDWARE REQUIREMENTS: | 100 mV shunt for 1, 2, 5, 10, 20, 50, or 100 Amps (MPS supplied). | |
| TEMPERATURE: | ||
| Operating: | -10°C to 50°C (14°F to 122°F) | |
| Storage: | -23°Ct o 60°C (-10°F to 140°F) | |
| Relative Humidity: | 0%to 95%, non-condensing | |
Order Codes:
VCM EE
Rating:
Class I Groups C & D and Class II Groups E,F & G.
Dimensions:
Height:: 7.6 in. (193 mm)
Length: 7.6 in. (193 mm)
Width: 7.8 in. (198 mm)
Weight: 15 lbs. (6.8 kg)