MPS

Products

VCM-EN SII

Overview

Dual Unit Solution; monitor TWO similar units or one VCM-E customized for a Turbine and one VCM-E customized for a Generator all in one enclosure.  Each VCM-E continuously monitors and outputs 4-20mA signals for shaft grounding currents and shaft voltages. 

This dual monitor is ideal for critical, large or high-speed rotating machinery requiring uninterrupted shaft grounding.  With two (2) VCM's in one enclosure, the single mounting option gives you the benefit of 2 separate monitors.

Key Benefits


The ability to monitor more than one location for

Early Warning of:

  • Loss of Shaft Grounding
  • High Residual Magnetism
  • Shaft or Rotor Rubs
  • Electrical Machinery Coil and Core Problems

 

 

Specifications

SPECIFICATIONS (Applicable to both Units A & B)   
 
 
TEMPERATURE:

			
Operating Temperature Range:
-10°C to 50°C (14°F to 122°F)
Relative Humidity:
    0% to 95%, non-condensing
Storage Temperature Range:
 
-23°C to 60°C (-10°F to 140°F)
 
POWER REQUIREMENTS:
 
100-240 Vac  50/60Hz input into the MPS supplied power supply.
 
INPUT:

			
    Current:100mV: 
(use shunt with 100mV/ full scale rating)

			
(Max. input voltage equals +/-10V)

			

			
    Voltage:  
+/- 1V    (Max. input voltage equals +/-5V)

			
+/- 10V  (Max. input voltage equals +/-50V)

			
+/- 100V(Max. input voltage equals +/-300V)

			

			
    Frequency                     Response:  
30 Hz to 10KHz

			

			
OUTPUT:

			
    Monitoring:

			
           Local:
 
 
3½ digit liquid crystal display, indicating Average Current,
Peak Current, Peak Voltage, and Power/Alarm Check,
selectable with rotary switch.
          Remote:
 
4 to 20 mA (Load impedance not to exceed 500 ohm)
                          signal representative of Peak Current.*

			
4 to 20 mA (Load impedance not to exceed 500 ohm)
                     signal representative of Average Current.*

			
4 to 20 mA (Load impedance not to exceed 500 ohm)
                 signal representative of Peak Shaft voltage.*
 
    Alarms:

			
          Local:
LED’s for high and low current and high voltage.*
          Remote:
 
 
Unified, single relay opening (10 watts, 0.5 A, and 100 Vdc)
(100Ω minimum load) for high and low current
                                                      and high voltage.*
 
NOTE:  Maximum shaft current is equal to shunt rating.
              Maximum shaft voltage is 1, 10, or 100 V (selectable).
 
DIMENSIONS
  

			
                     Length:
11.50 inches (29.21 cm) 

			
                     Width:
14.00 inches (35.56 cm)

			
                     Height:   4.75 inches (12.06 cm)  
                     Weight:
 
  5.60 pounds (2.6 kg)
 

			
* For shaft current monitoring and alarm, a 100 mV current shunt for 1, 2, 5, 10, 20
                                                                                                        50, or 100A is required.  
   For shaft voltage monitoring and alarm, a shaft voltage sensing device is required.

			

			

			

Order Code: VCM-ENSII


			

			

 

 

 


 

 

SAFEGUARDING MACHINERY WORLDWIDE SINCE 1980.

800-647-7372